70mm2 Double Insulated PVC Welding Cable

Jul 4, 2017

Welding Cable Specification Required

Standards Applicable: AS/NZS1995 Welding Cable, AS/ZNS5000.1 Power Cables

Conductor:                   100% Plain Copper Conductor to AS/NZS 1125

                                        Nominal 0.2mm stranding

Voltage Rating:             0.6/1kV

Insulation:                    PVC V-90 to AS/ZNS3808

Insulation Color:          White

Sheath:                           Nitrile (NBR) Modified PVC to comply to AS3808 V90HT

Sheath Color:                Orange, Black, Blue, Red

Packing:                         up to 70mm2 - 100m reels (no coils), 95mm2 up - 50m reels

Marking:                        Cable to be meter marked and ZW Branded (to be advised) 

Technical Specs:

Nominal

Area mm2

AMP

Construction +/-0.02mm

Wire X Number of Wires

Insulation

Thuckness mm

Sheath

Thickness mm

Overall Dia.

mm

16 150 513X0.20mm 1.10 1.10 10.00
25 200 795X0.20mm 1.10 1.10 12.50
35 300 1115X0.20mm 1.30 1.30 14.00
50 400 1590X0.20mm 1.30 1.30 16.00
70 500 2230X0.20mm 1.50 1.50 19.00
95 600 3000X0.20mm 1.80 1.80 21.50
120 800 1700X0.20mm 2.00 2.00 24.00

                                                         Please use the above specifications as a guideline for quotation.